Local Home Inspector
HI 00000 · (239) 555-0162
Report 26-0918
Sept 18, 2026
1994 canal home, SE Cape Coral
1,870 sq ft · block ranch · pool · 214 photos · inspected by Ray Castillo
- 2Safety
- 6Repair
- 9Monitor
- 3Credit
- 01
SafetyElectrical4-point
Federal Pacific Stab-Lok panel
Many Florida insurers won’t write a policy with one in the house. Ask the seller to replace it before closing.
Ask for Replace the panel. Licensed electrician, permit required.
- 02
RepairRoof4-point
Shingles are 17 years old
Most carriers want shingle roofs under 15 to 20 years. Get a roof certification or a replacement quote before you bind insurance.
Ask for Roof certification letter or replacement quote.

- 03
CreditRoof-to-wallWind mit
Single wraps at every truss we checked
One of the bigger wind mitigation credits, and most owners never file for it.

- 04
SafetyWater heater4-point
Relief valve is capped
A capped relief valve can’t release pressure. It’s a quick fix and a real hazard until it’s done. The tank is also from 2011.
Ask for Remove the cap and pipe the valve to the exterior.

- 05
RepairPlumbing4-point
Polybutylene supply lines in the attic
Gray plastic pipe common in homes from 1978 to 1995. Insurers flag it because the fittings fail without warning.
Ask for Repipe quote from a licensed plumber.

- 06
MonitorHVAC
Salt air corrosion on the condenser coil
Still cooling with an 18° split. Plan on replacing it in the next few years.

- 07
RepairExterior
Moisture under the window sill
Our meter read 28% and thermal imaging shows it spreading. Failed sealant, caught before the drywall went soft.
Ask for Reseal the window and open the drywall below it.

- 08
RepairPool cagePool
Corroded screws at two beam splices
Cheap to fix now. Expensive after a storm.
Ask for Replace the corroded fasteners at both splices.

- 09
RepairSewerSewer scope
Belly in the cast iron drain
The camera found standing water and scaling under the slab. Get a plumber’s quote inside your inspection period.
Ask for Plumber’s quote to line or replace the belly.
- 10
MonitorAtticWDO
Old drywood termite damage, treated
Frass and galleries on two trusses, with a tent tag from 2019. Documented on the WDO report for your lender.
Repair request list
- Electrical. Replace the panel. Licensed electrician, permit required.
- Roof. Roof certification letter or replacement quote.
- Water heater. Remove the cap and pipe the valve to the exterior.
- Plumbing. Repipe quote from a licensed plumber.
- Exterior. Reseal the window and open the drywall below it.
- Pool cage. Replace the corroded fasteners at both splices.
- Sewer. Plumber’s quote to line or replace the belly.